DONGSHIN hydraulics is always with you!
 
- Ethernet TCP/IP on board for communication to a host system
(whole production control) like a CIM (Computer integrated
Manutacturing) possible
- Access to set-up data via Microsoft Internet explorer from a
remote location (Option)
- Automatic linearization of hydraulic system
- Toggle linearization
- Ultra precise open-stop position of clamp, due to adjustable
ramping down of mould speed at end of opening stroke
movement
- Equipped with standard SPI core pulling sequences, as well
as provision for freely programmable core sequences
- High performance switchover - (Please explain what this
means)
- Back pressure can be varied during screw rotation phase via
closed loop control
- CLOSED-LOOP¸¦ ÅëÇÑ Heating Control(PID)
- Closed loop heating control (PID)
- "Soft start" function, to prevent water condensing in the mould
- "Trending" of temperature profile
- Automatic determination of "process capability" range shows
limits to variability within which any processing parameter can be
held. (ie statistical process control)
- Alarm logging and historical analysis of various monitored
parameters
- Metal housing of control modules - to minimise electromagnetic
disturbances
- Password protection for different levels of authorised input to he controls
- Injection pressure and velocity adjustable via 10 set points
- "Real time" data logging and "trend analysis" of parameters with graphical display to optimise machine set up